Model
Item code
JE275
116300
Power supply voltage
230V~ (+ 6% – 10%) 50/60 Hz
Max. power
7W
Motor max power
1.200W
Accessories power supply
24V
Max. accessories load
500mA
Operating ambient temperature
-20°C ÷ +55°C
Protection Fuses
F1 = 10A-250~ F2=T 0,8A-250~
Operating logic
Automatic, Automatic 1, Semi-automatic, Parking, Parking-Automatic, Condominium, Condominium-Automatic J Series, Manned, Remote, Custom
Work time
Programmable (from 0 to 4 min)
Pause time
Thrust power
Programmable on 50 levels
Terminal board inputs
Loop 1, Loop 2, Open, Close,Safety in closing, Stop, Emergency, 230V~ Power supply + Earth
Terminal board outputs
Flashing lamp, motor, Accessories power supply 24 VDC, Fail-Safe, Status output, 24V led lighting output, BUS
Rapid connector
Opening and closing limit switches, motor condenser
Programmable functions
Logic, Pause time, Thrust, Loop l and 2, Torque at initial thrust, Pre-flashing, Slow Closing, Deceleration time, Work time, LED output, Failsafe output, Status output, BUS output, Service Request
Integrated detector 2 independent channels
Real time self-calibration, sensitivity independent from loop geometry, loop operating frequency adjustment, message of “loop engaged” with LED display, loop status can be directed to programmable outputs, adjustment time over 2 levels.